Manufactured by JOBO, these intelligently-designed processors are suitable for up to 13"-width RA-4 and black and white prints. As with any roller-transport machine, the racks are the key to even, smooth, trouble-free printing. The design of the PrintLab ensures the paper is gently guided through the racks providing flawless processing.

PrintLabs 3503R and 3504 come pre-programmed for all RC-based B/W graded and variable contrast, and RA-4 papers. The rack design and variable temperature and transport speed controls assure you of high-quality processing.

PrintLab 3502 PrintLab Model 3502 - #7150

- RA-4, B/W, Duratrans
- 13" Maximum Width
- Built-in Washing Tray
- Stand-By Function
- Dryer Optional

PrintLab 3503 PrintLab Model 3503 - #7140

- RA-4, B/W, Duratrans
- 13" Maximum Width
- Dry-To-Dry
- Stand-By Function

PrintLab 3503R PrintLab Model 3503R - #7141

- RA-4, B/W, Duratrans
- 13" Maximum Width
- Dry-To-Dry
- Automatic Replenishment
- Computer-Controlled Operation
- Stand-By Function

PrintLab 3504 PrintLab Model 3504 - #7160

- RA-4, B/W, Duratrans
- 13" Maximum Width
- Dry-To-Dry
- Automatic Replenishment
- Computer-Controlled Operation
- Rinse-Water Heater
- Cleaning Program
- Stand-By Function

Back to Top

Where to Buy?


Key Features

Extremely consistent
All PrintLabs develop prints evenly and consistently. PrintLabs 3503R and 3504 take this consistency one step further with automatic replenishment.  These PrintLabs use five infrared sensors to measure the surface area of the print to be developed, then calculate and pump the correct amount of replenisher chemical to the appropriate bath. (The replenishment chemicals are drawn from collapsible 5-Liter air-tight containers.)

Easy on the environment
In addition to appropriate chemical replenishment, PrintLabs 3503R and 3504 use microprocessor-control to calculate the correct amount of wash water (based on the surface area of paper developed). Model 3503 automatically stops the wash water when the processor goes into standby mode.

Ready when you are
After turning on your processor, you're ready to start developing in minutes. With PrintLab models 3503R and 3504, each bath is independently heated to its specific temperature and controlled by an independent thermostat which allows for individual programming of each chemical bath. (There is one temperature control in models 3503 and 3502.)

Multiple small prints
Due to the unusual 13" (35cm) processing width, all PrintLab processors include the special ability to develop up to three 4x6" (10x15cm) prints simultaneously! The removable paper guide allows operators to easily load the small prints in the dark, and the light-tight paper feed cover allows you to turn on the lights immediately after loading the prints.
Multiple Prints

Special Features with PrintLab 3504
PrintLab model 3504 includes two special features to save you money and time.

The first is a built-in water heater for the rinse-water. These means only a cold-water supply is required. The other feature is a cleaning program. When the cleaning program is run the processor will automatically; drain the processing chemicals to bottles stored below, fill with water, wash the processing racks, drain itself, and wait until you're ready to start processing again.

Back to Top

Where to Buy?


Technical Specifications/Capacities:

Specification 3504 3503R 3503 3502
Maximum paper width 13.76" (35cm) 13.76" (35cm) 13.76" (35cm) 13.76" (35cm)
Number of tanks, Volume 4 (CD/Bx/W/W), 5-Liter 3 (CD/Bx/W), 5-Liter 3 (CD/Bx/W), 5-Liter 2 (CD/Bx), 5-Liter
Replenishment Automatic Automatic Manual Manual
In-feed sensors 5 5 1 1
Processing temperature Up to 40º C (±0.1º C) Up to 40º C (±0.1º C) Up to 40º C Up to 40º C
Dryer Hot air, adjustable, programmable Hot air, adjustable, programmable Hot air, adjustable No
Water consumption Two-tank reverse cascade, dependent on surface area of paper developed Dependent on surface area of paper developed Automatic shutoff of water when in stand-by mode Manual
Built-in rinse-water heater Yes No No No
Self cleaning option Yes No No No
Inline chemical filtration Yes Yes Yes Yes
Inline heaters CD, Bx, Rinse water CD, Bx CD, Bx CD, Bx
Warm-up time, from 20 to 35º C ~10 Minutes ~10 Minutes ~10 Minutes ~10 Minutes
Preprogrammed processes RA-4, B/W, Duratrans RA-4, B/W, Duratrans RA-4 RA-4
Power: 230V 230V/50 Hz 3000Watts 230V/50 Hz 1800 Watts 230V/50 Hz 2300 Watts 230V/50 Hz 1200 Watts
Power: 115V Not available 115V/60 Hz 1400 Watts 115V/60 Hz 1600 Watts 115V/60 Hz 600 Watts
Weight empty/full 88 / 133 Lbs 79 / 123 Lbs 77 / 121 Lbs 66 / 88 Lbs
Dimensions (LxWxH) 38x24x17" 31x24x17" 31x24x17" 31x24x13"

Back to Top

Where to Buy?


Accessories:

This chart illustrates which of the following accessories are used with which processors
Accessory 3504 3503R 3503 3502
3-Track Paper Feed Included Included Included Included
Wall Mount for 5-Liter Canister Included #7151 #7151 #7151
5-Liter Canister for Wall Mount 2x Included 2x #7164 2x #7164 2x #7164
Overflow Canister 2x Included 2x #7153 2x #7153 2x #7153
Support Stand #7161 #7156 #7156 #7156
Sealing Guide for Darkroom Installation #7162 #7162 #7162 #7162
Replenishment Container 2x Included 2x #7163 2x #7163 2x #7163
Processor Clean II #4135 #4135 #4135 #4135
Pressure Hose for Rinse Water Included Included Included Not Needed
External Water Pump #4212 Not Used Not Used Not Used
Roll Paper Attachment #7165 #7165 Call Not Used
Wall Mount Bracket and Container Refilling System
Filling and draining chemicals from the processing troughs is made easier with the Wall Mount and accompanying Canisters.

#7151 Wall Mount Bracket
#7164 Canister, Wall Mount

Overflow Canister Chemical overflow
Made of transparent plastic, these 5-Liter overflow canisters allow you to collect your used chemicals with little mess. Come complete with all necessary hoses.

#7153 Overflow Canister

PrintLab Support Stand Support stands
These heavy-duty stands provide a comfortable working height, and space underneath for overflow and replenishment chemicals containers.

#7156 Stand for models 3502, 3503, 3503R
#7161 Stand for model 3504

Sealing Guide Sealing guide
The Sealing Guide is used when the feed portion of the PrintLab is installed in a darkroom, but the processing portion of the processor is in "daylight".

#7162 Sealing Guide

Replenishment Chemicals Replenishing chemicals
To keep your replenishment chemicals fresh, use the 5-Liter collapsible container. Made with HDPE, an extremely air-tight plastic. Connects directly to the replenishment system of the PrintLab.

#7163 Reusable Replenishment Container

Roll Paper Attachment Roll paper
Increase your production with the Roll Paper attachment. The Roll Paper attachment holds over 300' of 12" roll paper. (Processor must be installed in a darkroom.)

#7165 Roll Paper Attachment

Back to Top

Where to Buy?


What's a less expensive alternative? What's the next step up?

The products immediately below the PrintLabs are split into two types: Print only dip-and-dunk style - NOVA Processors, or film and print rotary-tube processors - CPP-2 Processor.   Another line of roller-transport print processors we sell are the Fujimoto Processors.

Back to Top

Where to Buy?


jobo_logo_web.jpg (5206 bytes)

Send mail to info@omegasatter.com with questions or comments about this web site. Copyright © 1997-2005 JOBO Fototechnic, Inc. All rights reserved. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright to all of the photographs displayed on this site is owned by each of the photographers. You may not sell, publish, license or otherwise distribute any photographs without the written permission of the photographer.

 