Ultrafin Liquid
Development
Time and Temperature Table
Ultrafin Liquid is an all-round developer concentrate for
most Black and White roll and sheet films. Processing results can be varied by the
dilution of the developer concentrate. Ultrafin Liquid should be used as a one-shot
developer and mixed just prior to use. Ultrafin Liquid concentrate has excellent keeping
properties for up to 6 months in a tightly closed bottle.
Listed below are recommended times for
processing most popular films. Depending on your enlarger type, select the appropriate
table below. For diffusion, cold light and dichroic enlargers use table one (click
here). For condenser enlargers use table two (click here).
When processing in a JOBO rotary processor a five minute pre-soak is recommended.
All development times listed are for
processing at 20° Celsius (68° F). For processing at temperatures other than 20°
consult the time correction factors for various temperatures below (click
here).
For a Celsius to Fahrenheit temperature
conversion chart, go to the Conversion
Tables page.
Back to Top
TABLE #1 CONDENSER ENLARGERS
| Film Type/Speed |
Dilution
1:10 |
Dilution
1:20 |
Dilution
1:30 |
| |
Rotary |
Inversion |
Rotary |
Inversion |
Rotary |
Inversion |
| AGFA |
| AP-400 |
7:00 |
15:00 |
11:00 |
n/r* |
n/r* |
n/r* |
| APX-25 |
2:00 |
4:00 |
4:00 |
9:00 |
4:30 |
10:00 |
| APX-100 |
4:00 |
10:00 |
5:00 |
13:00 |
6:00 |
n/r* |
| FUJI |
| NEOPAN-400 |
4:30 |
9:00 |
8:00 |
n/r* |
14:00 |
n/r* |
| NEOPAN-1600 |
3:00 |
5:30 |
4:00 |
11:00 |
7:00 |
n/r* |
| ILFORD |
| PAN F PLUS |
n/r* |
3:00 |
4:30 |
5:30 |
3:30 |
9:00 |
| 100 DELTA |
n/r* |
n/r* |
4:30 |
10:00 |
n/r* |
n/r* |
| FP4 PLUS |
5:00 |
8:00 |
8:00 |
n/r* |
n/r* |
n/r* |
| HP5 PLUS |
4:30 |
n/r* |
8:00 |
n/r* |
n/r* |
n/r* |
| 400 DELTA |
8:00 |
n/r* |
9:00 |
n/r* |
n/r* |
n/r* |
| KODAK |
| HS-IR 2481 |
n/r* |
5:00 |
n/r* |
13:00 |
n/r* |
n/r* |
| TMAX 100 |
5:00 |
7:00 |
8:00 |
12:00 |
n/r* |
n/r* |
| TMAX 400 |
5:00 |
7:00 |
8:00 |
12:00 |
n/r* |
n/r* |
| TMAX 3200 |
5:30 |
8:30 |
8:00 |
n/r* |
n/r* |
n/r* |
| TRI X PAN |
5:00 |
9:00 |
7:00 |
n/r* |
n/r* |
n/r* |
| n/r* - Not Recommended |
Back to Top
Table #2
DIFFUSION, COLD LIGHT AND DICHROIC ENLARGERS
| Film Type/Speed |
Dilution
1:10 |
Dilution
1:20 |
Dilution
1:30 |
| |
Rotary |
Inversion |
Rotary |
Inversion |
Rotary |
Inversion |
| AGFA |
| AP-400 |
n/r* |
n/r* |
n/r* |
n/r* |
n/r* |
n/r* |
| APX-25 |
4:00 |
7:30 |
9:00 |
16:00 |
10:00 |
20:00 |
| APX-100 |
7:00 |
15:00 |
11:00 |
n/r* |
15:00 |
n/r* |
| FUJI |
| NEOPAN-400 |
9:00 |
17:00 |
18:00 |
n/r* |
n/r* |
n/r* |
| NEOPAN-1600 |
5:00 |
11:00 |
7:00 |
n/r* |
11:00 |
n/r* |
| ILFORD |
| PAN F PLUS |
n/r* |
4:30 |
3:30 |
9:00 |
5:00 |
15:00 |
| 100 DELTA |
n/r* |
n/r* |
9:00 |
n/r* |
n/r* |
n/r* |
| FP4 PLUS |
16:00 |
19:00 |
18:00 |
n/r* |
n/r* |
n/r* |
| HP5 PLUS |
12:00 |
n/r* |
n/r* |
n/r* |
n/r* |
n/r* |
| 400 DELTA |
n/r* |
n/r* |
n/r* |
n/r* |
n/r* |
n/r* |
| KODAK |
| HS-IR 2481 |
3:00 |
8:00 |
7:00 |
20:00 |
14:00 |
n/r* |
| TMAX 100 |
8:30 |
12:00 |
14:00 |
n/r* |
n/r* |
n/r* |
| TMAX 400 |
8:30 |
12:00 |
14:00 |
n/r* |
n/r* |
n/r* |
| TMAX 3200 |
9:00 |
13:00 |
11:00 |
n/r* |
n/r* |
n/r* |
| TRI X PAN |
9:00 |
n/r* |
12:00 |
n/r* |
n/r* |
n/r* |
| n/r* - Not Recommended |
Back to Top
Time correction factors for
various temperatures.
For processing temperatures other than 20°
Celsius find the film and recommended development time in table one or two and multiply by
the appropriate factor listed below.
| 18°C (64° F) |
20°C (68° F) |
22°C (72° F) |
24°C (75° F) |
26°C (79° F) |
1.2 |
1 |
.85 |
.75 |
0.6 |
Back to Top
If you have any questions, contact us utilizing one of the
following methods:
Equipment or Processing Questions:
- Phone: Customer Service Department (734) 205-9421
e-mail: tech@jobo-usa.com
Repair Questions:
- Phone: Repair Department (734) 205-9420
- e-mail: repair@jobo-usa.com
- Telephone (734) 677-6989
- Fax: (734) 677-6963
-
- Postal address
- P.O. Box 3721, Ann Arbor, MI 48106
- Shipping Address
- 4401 Varsity Drive, Suite D, Ann Arbor, MI 48108
- Electronic mail
- Sales: sales@jobo-usa.com
- Equipment & Processing Questions: tech@jobo-usa.com
Repair Information: repair@jobo-usa.com
- Shipping or Billing Questions: help@jobo-usa.com
Webmaster: webmaster@jobo-usa.com
-
Back to Top