Tank and Drum Capacities
Introduction
This information is the most current as of its posting.
Please use this information, if there is a conflict with previously published materials.
Back to Top
Important
There are many things to consider when determining the
volume requirements for processing.
The 'Minimum Volume' stated in the charts below is just the
amount of solution that is required to physically cover the film or paper with a level of
solution. Never run a process with less than this volume of solutions. Partially
unprocessed film or prints will result when using too low a volume.
These volumes are for rotary processing only.
If these tanks or drums are used in any other fashion, such
as inversion (hand) techniques, or any procedure that does not have constant agitation,
more volume will be required.
These minimums require accuracy.
Accurately measure your volumes. The tank or drum has to be
completely level. If the tank or drum end facing away from the magnet or lift coupling is
floating above the rollers, the higher end will not be sufficiently covered in solutions.
Adjust the level of the water bath until the end no longer floats.
Place a level on the tank or drum. Adjust the leveling of the
processor, if necessary.
The 'Minimum Volume' is not necessarily the volume you
need to use for processing.
Consider the requirements of your specific chemicals, in
combination with the specific film or paper being processed. Note extended dilution (if
used). Be sure that the volume required for the square footage (or meters) is sufficient
to properly process the amount of film or paper in your tank or drum.
If you are unsure of these requirements, check with the
chemical or film manufacturer for their specifications. In all cases, if this volume
required for the amount of film or paper is higher than the 'Minimum Volume', use the
chemical manufacturer's requirements as your "minimum".
Always compare these two figures and use the higher one as
your "minimum."
When in doubt, use a higher volume of solutions.
The 'Minimum Volume' is just that, a minimum. Using more than
a minimum amount will not harm virtually any process. Extra volume of chemicals will not
"over develop" your film or paper. (Note, however, the precautions in the next
section regarding processor limits.)
If your film or paper is coming out
"underdeveloped" it could be caused from too little volume of chemicals. If this
is the case, extending the development time will not completely cure the
"underdevelopment." Increase the volume of chemicals used. An excess volume of
chemicals will not "over develop" your film or paper.
Never use a tank or drum loading that exceeds the
processor's specifications.
Do not use any combination of chemicals, tanks, reels, drum,
and amount of film or paper, that is going to require more volume of solutions than the
maximum recommended volume stated for your processor. Doing so will shorten the life of
the processor's rotation motor and other components.
When using extended dilutions of the developer, you may need
to limit the number of films put in some of the larger tanks or Expert Drums. This
prevents the resultant volume of solution from being more than the recommended maximum
safe capacity of the processor.
See the 'Footnotes' for specific
warnings about over capacity.
Back to Top
Index
This Page:
Links to Related Pages:
Back to Top
Film Tanks
and Reels
Back to Top
1500
Series Tanks with 1501 Reels
| Film Tanks |
35mm |
120 |
220 |
Center
Core |
Minimum
Volume |
Notes |
| 1510 Tank |
1 |
na |
na |
04043 |
140 ml (4 3/4 oz) |
35mm only, 4 |
| 1520 Tank |
2 |
2 |
1 |
04044 |
240 ml (8 oz) |
4 |
| 1530 Module |
3 |
4 |
2 |
04045 |
330 ml (11 1/4 oz) |
6 |
| 1540 Tank (1510 +
1530) |
4 |
4 |
2 |
04043+04045 |
470 ml (16 oz) |
4 |
| 1526 Tank (1520 +
1530) |
5 |
6 |
3 |
04044+04045 |
570 ml (19 1/4 oz) |
4 |
| 1510 Tank +
(2x)1530 |
7 |
8 |
4 |
04043 + (2x)04045 |
800 ml (27 oz) |
1, 4, 5 |
| 1520 Tank +
(2x)1530 |
8 |
10 |
5 |
04044 + (2x)04045 |
900 ml (30 1/2 oz) |
1, 4, 5 |
Back to Top
1500 Series Tanks with
Stainless Steel Reels
| Film Tanks |
35mm
(1555) |
120
(1557) |
220
(1559) |
Center
Core |
Minimum
Volume |
Notes |
| 1520 Tank |
1 |
1 |
1 |
1561 |
300 ml (10 1/4 oz) |
4 |
| 1540 Tank (1510 +
1530) |
4 |
2 |
2 |
1562 |
500 ml (17 oz) |
4 |
| 1526 Tank (1520 +
1530) |
5 |
3 |
3 |
1563 |
600 ml (20 1/4 oz) |
4 |
| 1520 Tank +
(2x)1530 |
8 |
5 |
5 |
1564 |
950 ml (32 oz) |
1, 4, 5 |
Back to Top
2500
Series Tanks with 2502 Reels (with any film loaded inside of the red clip)
| Film Tanks |
35mm |
120 |
220 |
Center
Core |
Minimum
Volume |
Notes |
| 2513 Tank |
1 |
na |
na |
04043 |
170 ml (5 3/4 oz) |
35mm only |
| 2521 or 2523 Tank |
2 |
2 |
1 |
04044 |
270 ml (9 1/4 oz) |
2521 magnet, 2523 cog |
| 2551 or 2553 Tank |
5 |
6 |
3 |
04044 + 04045 |
640 ml (21 3/4 oz) |
2521 magnet, 2523 cog, 1 |
| 2560 Module |
6 |
6 |
3 |
(2x) 04045 |
850 ml (28 3/4 oz) |
1 6 |
| 2563 Tank |
6 |
6 |
3 |
04044 + 04045 + 04073 |
850 ml (28 3/4 oz) |
1 |
| 2583 Tank (2523 +
2560) |
8 |
10 |
5 |
04044 + (2x) 04045 |
1250 ml (42 1/4 oz) |
1 2 |
| 2593 Tank (2553 +
2560) |
12 |
14 |
7 |
04044 + (3x) 04045 |
1500 ml (50 3/4 oz) |
1 2 5 |
Back to Top
2500
Series Tanks with 2502 Reels (120 only, none loaded inside the red clip, 1 roll per reel)
| Film Tanks |
120 |
Center
Core |
Minimum
Volume |
Notes |
| 2521 or 2523 Tank |
1 |
04044 |
170 ml (5 3/4 oz) |
2521 magnet, 2523 cog |
| 2551 or 2553 Tank |
3 |
04044 + 04045 |
330 ml (11 3/4 oz) |
2551 magnet, 2553 cog |
| 2560 Module |
4 |
(2x) 04045 |
400 ml (13 1/2 oz) |
6 |
| 2563 Tank |
4 |
04044 + 04045 + 04073 |
400 ml (13 1/2 oz) |
|
| 2583 Tank (2523 +
2560) |
5 |
04044 + (2x) 04045 |
620 ml (21 oz) |
1 |
| 2593 Tank (2553 +
2560) |
7 |
04044 + (3x) 04045 |
800 ml (21 oz) |
1, 5 |
Back to Top
2500 Series Tanks with 2509N Reels
| Film Tanks |
4x5" |
Center
Core |
Minimum
Volume |
Notes |
| 2521 or 2523 Tank |
6 |
04044 |
270 ml (9 1/4 oz) |
2521 magnet, 2523 cog |
| 2551 or 2553 Tank |
12 |
04044 + 04045 |
560 ml (19 oz) |
2551 magnet, 2553 cog |
| 2560 Module |
12 |
(2x) 04045 |
730 ml (24 1/4 oz) |
1, 6 |
| 2563 Tank |
12 |
04044 + 04045 + 04073 |
730 ml (24 1/4 oz) |
1 |
| 2583 Tank (2523 +
2560) |
18 |
04044 + (2x) 04045 |
1000 ml (33 1/4 oz) |
1 |
| 2593 Tank (2553 +
2560) |
24 |
04044 + (3x) 04045 |
1250 ml (42 1/2 oz) |
1, 2, 5 |
Back to Top
Print Drums
| Print Drums |
4x5" |
5x7" |
8x10" |
11x14" |
16x20" |
20x24"
|
Minimum
Volume |
Notes |
| 2820 Test Drum |
2 |
na |
na |
na |
na |
na |
40 ml (1 1/4 oz) |
4 |
| 1526 Combo |
na |
1 |
1 |
na |
na |
na |
50 (1 3/4 oz) |
4 |
| 2830 Drum |
na |
4 |
2 |
na |
na |
na |
100 ml (3 1/2 oz) |
4 |
| 2840 Drum (2820 +
2870) |
na |
4 |
2 |
1 |
na |
na |
120 ml (4 oz) |
4 |
| 2850 Drum (2830 +
2870) |
na |
8 |
4 |
2 |
1 |
na |
200 ml (7 oz) |
4, 5 |
| 2870 Module |
na |
4 |
2 |
na |
na |
na |
100 ml (3 1/2 oz) |
6 |
| 3062 Drum |
na |
9 |
3 |
2 |
na |
na |
210 ml (7 1/4 oz) |
5 |
| 3063 Drum |
na |
12 |
6 |
2 |
1 |
1 |
300 ml (10 1/4 oz) |
5 |
Back to Top
Expert Drums
| Expert Drums |
4x5" |
5x7" |
8x10" |
8.5x12" |
Minimum
Volume |
Maximum
Volume |
Notes |
| 3004 Expert |
na |
4 |
4 |
4 |
270 ml (9 1/4 oz) |
1500 ml (50 3/4 oz) |
2, 5 |
| 3005 Expert |
na |
5 |
5 |
na |
270 ml (9 1/4 oz) |
1500 ml (50 3/4 oz) |
2, 5 |
| 3006 Expert |
6 |
6 |
na |
na |
210 ml (7 1/4 oz) |
1000 ml (33 1/4 oz) |
5 |
| 3010 Expert |
10 |
na |
na |
na |
210 ml (7 1/4 oz) |
1000 ml (33 1/4 oz) |
5 |
Back to Top
Footnotes
- The CPE-2 and CPE-2 Plus
should not be used with more than 600 ml of solution. Excess volumes will limit the useful
life of the rotation motor.
- The CPA-2 and CPP-2 processors
should not be used with more than 1000 ml of solution. Excess volumes will limit the
useful life of the rotation motor. The ATL's 1, 2, 2 Plus and 2000 cannot be used with
more than 1000 ml of solution.
- The ATL's 3 and 3000 cannot be
used with more than 1500 ml of solution.
- This tank or drum requires a Cog #1505 to be
installed before using it on a JOBO Lift or an ATL processor, or a Magnet #1504 for use
with a magnet drive processor.
- This tank or drum is too large to fit
the CPE-2 or CPE-2 Plus processors.
- All Modules must be used with a tank or
drum. They cannot be used alone.
Back to Top
If you have any questions, contact us utilizing one of the
following methods:
Equipment or Processing Questions:
- Phone: Customer Service Department (734) 205-9421
e-mail: tech@jobo-usa.com
Repair Questions:
- Phone: Repair Department (734) 205-9420
- e-mail: repair@jobo-usa.com
- Telephone (734) 677-6989
- Fax: (734) 677-6963
-
- Postal address
- P.O. Box 3721, Ann Arbor, MI 48106
- Shipping Address
- 4401 Varsity Drive, Suite D, Ann Arbor, MI 48108
- Electronic mail
- Sales: sales@jobo-usa.com
- Equipment & Processing Questions: tech@jobo-usa.com
Repair Information: repair@jobo-usa.com
- Shipping or Billing Questions: help@jobo-usa.com
Webmaster: webmaster@jobo-usa.com
-
Back to Top