Introduction
To use a tank or drum on the processor (without the JOBO
Lift attached) a magnet must be mounted on its bottom. You must have a cog installed on a
tank or drum lid to allow coupling with the accessory JOBO Lift or Autolab processor.
Some tanks and drums come with a magnet or cog already
installed, some do not. At least one of these mounting systems must be present to use a
tank or drum on the processor. See the instructions below to determine if you need to
obtain a magnet or cog for the tanks or drums you own, or intend to purchase.
The mounting procedures below will prepare your tank or
drum for use on your JOBO rotary processor.
Mounting
a Magnet On a Tank or Drum
To use a tank or drum on a manual processor (without the
JOBO Lift attached), a magnet must be mounted on its bottom. A magnet is not required for
any of the Autolabs.
The Magnet, part number 1504, will allow you
to use 1500, 2500, and 2800 series tanks or drums on a magnet drive processor. (The 3000
series drums are too large in diameter to use a magnet coupling.) This magnet is
permanently attached to the tank or drum in the following sequence. You will need one
magnet for each tank or drum you wish to use.
- Remove the lid from the tank or drum.
- Note the location of the four pins on the magnet. Note also
the four short raised tubes on the bottom of the tank or drum.
- Place the tank or drum upside down on a smooth, hard
surface.
- Align the four pins with the raised tubes, and press the
magnet down vigorously.
- Check that there is no gap between the magnet and the bottom
of the tank or drum.
When the magnet is properly mounted, it should
not come off. If the magnet does not stay securely on the tank or drum, follow this
procedure. After doing the above steps, turn the tank or drum right side up. Place a piece
of wood (such as a 2x4") slightly longer than the depth of the tank or drum, into the
bottom of the tank. Center the piece of wood in the tank. Rap the top end of the wood with
a hammer. Inspect the mounted magnet for gaps. Repeat if necessary.
WARNING: Do not try and mount the magnet on the tank
by pounding on the magnet. This will likely damage the magnet or split the tank.
To use a magnet-equipped tank or drum on a JOBO Lift
equipped processor or Autolab, simply add a Cog (#1505) to the lid. Do not remove the
magnet when using the tank or drum on the JOBO Lift or Autolab.
If you are purchasing a tank or drum, note its four-digit
part number. If the part number ends in '1' (such as 2521 or 2551, etc.), it already has a
magnet attached. All other tanks and drums do not come equipped with a magnet. Tanks that
have the last number of '3', have cog type lids. These lids would have to be replaced to
use them with a magnet drive processor. Replacement lids (without cap, funnel, or beaker)
are available as parts from JOBO. The 1500 series requires #91034, and both the 2500 and
the 2800 series require a #91036 lid. (There is no non-cog lid available for the 3000
series drums.) The #03046 membrane cap is needed by all three series lids.
Back to Top
Mounting a Cog
On a Lid
You must have a cog installed on a tank or drum lid to
allow coupling with the JOBO Lift or Autolab. Some tanks come with the cog already
installed. If you are purchasing a tank, check the JOBO part number of the tank. If the
first or last digit of the four digit code is a '3' (3010, 2523, etc.), then there is
already a cog installed in the lid. If the first or last digit is not a '3', then you will
need to purchase a Cog (#1505) for the tank or drum.
One cog for each tank or drum is required, as
they are permanently mounted into the lid, and cannot be removed. If you wish to keep the
lid for hand or magnet processing, get a replacement cog lid. The JOBO part number for the
replacement cog lid in the 1500 series is #1503. Both the 2500 series and the 2800 series
use the same replacement lid, #2503. This replacement lid comes with a funnel and a
stopper. (The stopper is placed in the funnel only when replacing the beaker. The
stoppered funnel is used exclusively for print processing with a lift.) The 3000 series of
drums cannot be used with the magnet drive. 3000 series lids are always supplied with a
cog.
You may use the lift with a tank or drum having a magnet
attached on the bottom. The daylight loading tank #2400, or the discontinued series 1000,
2000, and 4000 tanks or drums cannot be equipped with a cog.
The procedure for mounting a cog is the same for all tank
or drum lids.
- Remove the lid from the tank or drum. Remove the red
membrane cap and funnel or beaker.
- Place the lid, red ring down, on a hard and smooth surface.
- Place the cog, wide side down, into the opening for the cap,
at a slight angle.
- Press the cog down with your hands. (You may find it helpful
to lean towards the lid to apply a firm pressure.)
- Examine the seam between the cog and the lid for gaps. When
seated correctly, there will be no gap between the cog and lid. (If you can place a
fingernail between them, the cog is not seated fully.)
If you cannot seat the cog fully, by hand, use
this procedure. Seat the cog as far as you can by hand. Place a flat piece of wood, on top
of the cog. Rap the board smartly (centered over the cog) with a hammer. Repeat as
necessary until the cog is fully seated.
If the cog comes off the lid during processing, it was not
completely seated. Re-seat the cog.
The cog has a small (1 1/2" or 35 mm) red ring that
functions as a washer and seal between the lid and lift. It is located just inside the
gear ring. This ring will wear with long, heavy use, and may need replacement. If you find
the washer is staying on the lift when you remove the tank or drum, replace it. The cog
lid washer's part number is #07095. The tank lids that come with the ATL-1000 processor do
not have a washer installed in the lid. If you wish to use one of these lids, be sure to
place a washer in the lid. If you use a lid without a washer, the junction of the JOBO
Lift and tank will leak.
Never try to remove an installed cog from its lid, as you
will break either the cog or the lid.
Back to Top
If you have any questions, contact us utilizing one of the
following methods:
Equipment or Processing Questions:
- Phone: Customer Service Department (734) 205-9421
e-mail: tech@jobo-usa.com
Repair Questions:
- Phone: Repair Department (734) 205-9420
- e-mail: repair@jobo-usa.com
- Telephone (734) 677-6989
- Fax: (734) 677-6963
-
- Postal address
- P.O. Box 3721, Ann Arbor, MI 48106
- Shipping Address
- 4401 Varsity Drive, Suite D, Ann Arbor, MI 48108
- Electronic mail
- Sales: sales@jobo-usa.com
- Equipment & Processing Questions: tech@jobo-usa.com
Repair Information: repair@jobo-usa.com
- Shipping or Billing Questions: help@jobo-usa.com
Webmaster: webmaster@jobo-usa.com
-
Back to Top