7.1 When to run a cleaning program
7.2 Filling the bottles with water
7.3 Running the cleaning program

Back to Top


7.1 When to run a cleaning program

The ATL-1500 should be cleaned at the end of each processing session or when changing from one process to another. It is not necessary to run a cleaning program if you're repeating the same process you just ran (unless you've mixed new chemicals).

The cleaning program should be repeated three times when changing from one process to another to eliminate any chance of contamination.

Back to Top


7.2 Filling the bottles with water

The first step in running the cleaning program is filling all the bottles with water. This is accomplished by performing the following steps:

  1. Remove rinse-water hose (#21) from the storage position.
  2. Place nozzle of hose in bottle #1 and press the RINSE button (#7) until the bottle is full.
  3. Repeat step 2 for all six bottles if you're running the 1-6 cleaning program, or for the first three bottles if you're running the 1-3 cleaning program.
  4. Put the hose back into the storage position.
  5. When using the portable pump #4212, the rinse-water hose does not operate. You'll need to fill the bottles with water manually.

Back to Top


7.3 Running the cleaning program

After filling all bottles with water perform the following steps:

  1. Select one of the cleaning programs (#15 or #16) with the Program Selector Knob (#9).
  2. Close all bottle lids (#18).
  3. Confirm the rinse-water hose (#21) has been returned to the storage position.
  4. Attach the large tank to the processor.
  5. Close the top cover (#11).
  6. Make sure there is sufficient space in the drain canisters to hold the water.
  7. Press the ON/OFF Button (#10).
  8. Wait for beep that signals the end of the process.

Back to Top


If you have any questions, contact us utilizing one of the following methods:

Equipment or Processing Questions:

Phone: Customer Service Department (734) 205-9421
e-mail: tech@jobo-usa.com

Repair Questions:

Phone: Repair Department (734) 205-9420
e-mail: repair@jobo-usa.com

JOBO Contacts

Telephone (734) 677-6989
Fax: (734) 677-6963
 
Postal address
P.O. Box 3721, Ann Arbor, MI 48106
Shipping Address
4401 Varsity Drive, Suite D, Ann Arbor, MI 48108
Electronic mail
Sales: sales@jobo-usa.com
Equipment & Processing Questions:  tech@jobo-usa.com
Repair Information: repair@jobo-usa.com
Shipping or Billing Questions: help@jobo-usa.com
Webmaster: webmaster@jobo-usa.com
 

Back to Top


jobo_logo_web.jpg (5206 bytes)

Send mail to webmaster@jobo-usa.com with questions or comments about this web site. Copyright © 1997-2005 JOBO Fototechnic, Inc. All rights reserved. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright to all of the photographs displayed on this site is owned by each of the photographers. You may not sell, publish, license or otherwise distribute any photographs without the written permission of the photographer.

 

This page last updated on 03/20/02